The advantages in overview:
- Fastest possible response and decay time; no delay times
- No interference by thoron (Rn-220 – will be measured separately)
- No long term contamination by Po-210 even at permanent measurements at high radon concentrations
The unit comes in a very robust and handy case for use in harsh environmental conditions. A signal light at the top of the case indicates the end of a measurement or warns in case of very low soil permeability.
The powerful software dVISION provides all functions for data management including the display of results in the integrated map (Google™ based) as well as the export to CSV or KML files.
Of course, all functions required for typical applications (long- and short-term measurements, searching for entry paths, radon in water, or radon exhalation) are implemented in the RTM 2200.
Additional options:
- TDR probe for simultaneous measurement of the soil moisture as another important parameter for the evaluation of the radon potential
- Blower door kit: contains a high-precision and long-term stable differential pressure sensor for very small pressure drops (range 0 … 25 Pa) to measure pressure differences between individual rooms. This function is necessary to investigate radon transportation in buildings
- Sensors for CO2 and CH4 integrated in the internal air loop
Specifiche
Radon chamber +Detector: 4 x 200mm² ion-implanted silicon detector
+Internal volume: 3000mm³ (total volume of the internal air loop)
+Range: 0…10 MBq/m³
+Sensitivity: 3 or 7 cpm/(kBq/m³) for fast or slow mode
+Response time: 12 or 120 min for fast or slow mode
Analysis/Results: Alpha spectroscopy with a separate calculation of Radon and Thoron concentration. Storage of the alpha spectrum for each data record.
+Pump: High-quality membrane pump; Flow rate of 0.5 l/min controlled by a processor
+Fresh air flushing: Automatic switch over between fresh air and sample air inlet
Soil permeability +Principle: Measurement of the pressure difference at a regulated flow rate (1 l/min)
+Range: 8 *10-12 m² … 8 * 10-14 m²
+Sampling: Tube connection to soil gas probe
Protection functions +Battery voltage: Measurement will be stopped in case of a discharged battery; hardware protection against deep discharge.
+Flow rate: Alert signal if the flow rate cannot be maintained by the regulator.
+Pump power consumption: Measurement will be stopped in case of a damaged or worn pump.
+Water inlet protection: Pump will be stopped as soon as water is sucked. Stainless steel can may be removed to drain the water.
Internal sensors +Rel. humidity: 0 …100%, accuracy ± 2%
+Temperature: -20 … 40°C, accuracy ± 0.5°C
+Bar. pressure: 800 … 1200mbar, accuracy 0.5% MW
+Flow rate: 0 … 2 l/min, accuracy ± 5% @ 1 l/min
Humidity/temperature sensors are integrated into the air internal air loop
Common +GPS receiver: High accuracy by simultaneous reception of GPS, Galileo and GLONASS
+Sampling programs: Continuous sampling (1, 5, 15, 30 and 60 minutes), Soil gas cycle (20 minutes), Additional cycles may be programmed by the user
+Memory: SD card, 2 GB (approx.. 1 million data records)
+Control/Display: Touch screen 6 x 9 cm wide, visible in direct sunlight
+Interfaces: USB and RS232
+Power supply: Internal 12V NiMH rechargeable battery, AC/DC wall adapter
+Dimensions/weight: 235mm x 140 mm x 255 mm / approx. 6 kg (instrument only)
+Case: Peli case 1430 with bulkhead fittings and signal light, (W x D x H: 417 mm x 221 mm x 334 mm; weight 2.9 kg)
+Software: dVISION/dCONFIG; server software for instrument access via internet
+Included in delivery: Instrument with cases, 12V/60VA AC/DC adapter, USB – cable
+Options: TDR soil moisture probe, Differential pressure sensor 0 … 25 Pa, More sensors on request
Specifiche (formato pdf in inglese)
Garanzia
SARAD GmbH offre una garanzia generale di 24 mesi per i clienti nei paesi dell'Unione europea e 12 mesiper i clienti al di fuori dell'UE. Il periodo di garanzia inizia con il ricevimento della merce da parte del cliente. Ci riserviamo il diritto di rettificare.

Il team NITON srl nasce nel 2017 dalla volontà di creare un gruppo di persone che si sono scelte, unite dalla condivisione degli stessi valori professionali ed umani: dedizione al lavoro, onestà intellettuale, etica e rispetto dell’ambiente a 360°.
Professionisti del Radon accreditati dall’NRPP: Niton è la prima ed unica società in Italia che si avvale, per i rilievi Radon, di professionisti certificati dal National Radon Proficiency Program (NRPP) degli Stati Uniti. Perché quando affermiamo di essere specialisti del Radon, abbiamo le carte per dimostrarlo!
FIDOtrack: FIDOtrack è il sistema di misura della concentrazione di Radon per il medio e lungo periodo. Semplice da usare, ricevi i rivelatori, li posizioni, al termine del periodo di esposizione ce li rimandi e ricevi via e-mail un certificato ufficiale con l’esito delle misure. Niton è risultato uno dei migliori laboratori europei nella prova di Interconfronto 2019 organizzato dall’Istituto Tedesco Bfs, con i propri rivelatori FIDOtrack.
Aspiratori di Radon: NITON srl è distributore ufficiale dei prodotti RadonAway ed è distributore esclusivo degli aspiratori RadonAway in Italia.
Cerchi un professionista del Radon per un’indagine approfondita del tuo immobile? Contattaci al numero 0222197130 o tramite e-mail all’indirizzo [email protected]
Recensioni
There are no reviews yet